KLAS spec sheet · Outlets

KLAS
Spec sheet · Outlets

Outlets

Tamper-resistant receptacles in a solid brass plate · hand-brushed, naturally unique on every plate

Duplex, GFCI and USB outlets in satin brass plates, black devices

Duplex · GFCI · USB-A + USB-C, shown on satin brass. Dual USB-C below

Duplex outlet GFCI outlet USB outlet Dual USB-C outlet
Use Everyday sockets Near water: kitchens, bathrooms, laundry, outdoors. Test / reset buttons Two sockets plus built-in charging Two sockets plus two fast-charging USB-C ports
Rating 15 A or 20 A · 120 V AC. The 20 A version has a T-shaped neutral slot and must be on a 20 A circuit; a 15 A outlet is allowed on a 20 A circuit when there are two or more outlets on it. Dual USB-C: 15 A
Tamper-resistant Yes (TR), as required in US homes
USB ports None None 1 × USB-A, 1 × USB-C 2 × USB-C
Fits Standard 1-gang US/Canada box (per gang)
Certification UL, US & Canada · UL 498 / CSA C22.2 No. 42 (receptacles) · UL file E481372
Device colour White, black or ivory
Plate 2 mm solid brass on a 2 mm acrylic frame
In the box Plate, outlet fitted, matching screws
Duplex outlet in white, black and ivory

Device colours: white · black · ivory

Dual USB-C outlet in antique brass and brushed nickel plates

Dual USB-C outlet · two sockets + two USB-C ports, white or black

Plate sizes

Gangs 1 2 3 4 5 6
Width (mm) 72 120 165 210 255 300
Width (in) 2.83 4.72 6.50 8.27 10.04 11.81
Height 120 mm · 4.72 in · screw holes 83.5 mm (3.29 in) apart, inch screws

Wiring

HOTNEUTRALGROUND brass screw → hotsilver screw → neutralgreen screw → ground

GFCI: incoming power to LINE terminals; LOAD terminals protect outlets further down the circuit.

Installation

Install by a licensed electrician with the power off at the breaker, following local codes. Press TEST then RESET on a GFCI after installation, and monthly.

Handle Shop Couture · handleshopcouture.com · Specifications may change; ask us to confirm before installation. Made to order and non-returnable.